0102030405
China Intelligent Electric Safe Initiation System - Shooting Panel for Electronic Detonators | Suppliers & Factory
Product Description
The shooting panel (Intelligent Electric Safe Initiation System) is specialized used as power supply for electric initiation (Electric Detonator, Igniter) as well as the DC power supply for magnetizing implement. By way of changing the position of the Wireline and the GND, we could also make the positive and negative current output respectively to achieve the purpose of initiation for twice.
The power supply fulfills the large current of AC output with wide voltage range, and uses the electronic isolation technology and current filter technology which could effectively isolate the grid and voltage (To prevent the leakage protection switch from tripping when initiating) and enhance the stability and antijamming capability of the output voltage to make it work more reliably. It also uses the over current time-delay protection circuit, which could automatically cutoff the output when the duration of ignition reaches two second and this can protect the control panel from breakdown.
✅ This Intelligent Electric Safe Initiation System is used in concert with our Digital Electronic Explosion-proof Safety Switch, bringing benefits of anti-static, anti-creep and preventing operators from wrong operation. It overcomes the shortage of Mechanical Pressure Explosion-proof Safety Switch, thus preventing the occurrence of detonated by mistake on ground or perforated by mistake in the pit.
📋 Directions
- 1 Select the corresponding output voltage according to the detonator's initiating voltage. If the length of the electric cable is more than 3000 meters, it is necessary to add an additional voltage of 10V~30V according to its length to ensure the reliable initiation.
- 2 Connect the Wireline plug and GND correctly according to the requirement.
- 3 Turn on the power switch and safety switch successively, then push the Firing Switch button (for four seconds) when confirmed, finally release the button when there is no output current.
- 4 Turn off the power switch and safety switch successively, then unplug the Wireline plug and GND plug. The initiation control panel should be placed in a safe position after the operation has been finished.
Specifications
| Type | Input Voltage (V) | Output Voltage (V) | Input Current (A) | Output Current (A) | Continuous Operation Time (s) | Frequency (Hz) | Temperature Rating (°C) |
|---|---|---|---|---|---|---|---|
| HY-Ⅰ | 220 | 280~400 | 1.8 | ≤2A | 5 | 50~60 | -5~45 |
| HY-Ⅱ | 350~450 | 3 |
⚠️
If you are not properly trained in the handling and use of explosive devices, do not attempt the assembly of any FYPE Perforating Systems or Firing Devices.
Frequently Asked Questions
Q
What is the Intelligent Electric Safe Initiation System used for?
The Intelligent Electric Safe Initiation System (shooting panel) is primarily used as a power supply for electric initiation devices such as Electric Detonators and Igniters. It also serves as a DC power supply for magnetizing implements. By repositioning the Wireline and GND connections, both positive and negative current outputs can be achieved, enabling initiation twice.
Q
How does the system prevent accidental detonation or wrong operation?
When used together with the Digital Electronic Explosion-proof Safety Switch, the system provides anti-static, anti-creep, and operator error prevention features. This combination overcomes the limitations of traditional Mechanical Pressure Explosion-proof Safety Switches, significantly reducing the risk of accidental detonation on the ground or unintended perforation in the pit.
Q
What should I do if the electric cable length exceeds 3000 meters?
If the electric cable length exceeds 3000 meters, you should add an additional voltage of 10V to 30V beyond the standard initiating voltage of the detonator. The exact amount of additional voltage should be determined based on the actual cable length to ensure reliable and safe initiation.
Q
What is the purpose of the over current time-delay protection circuit?
The over current time-delay protection circuit is a built-in safety feature that automatically cuts off the output when the duration of ignition reaches two seconds. This protects the control panel from damage caused by prolonged current flow, extending the service life of the equipment and ensuring safe operation.
Q
What are the input and output voltage specifications for the HY-Ⅰ and HY-Ⅱ models?
Both models operate on an input voltage of 220V at 50~60Hz. The HY-Ⅰ model provides an output voltage range of 280V to 400V with a continuous operation time of 5 seconds, while the HY-Ⅱ model provides an output voltage range of 350V to 450V with a continuous operation time of 3 seconds. Both models share an input current of 1.8A, output current of ≤2A, and a temperature rating of -5°C to 45°C.
Q
Who is authorized to operate the FYPE Perforating Systems or Firing Devices?
Only personnel who have received proper training in the handling and use of explosive devices are authorized to operate or assemble FYPE Perforating Systems or Firing Devices. Untrained individuals must not attempt to use or assemble these systems, as improper handling can result in serious injury or fatal accidents.