Product Description
The shooting panel (Intelligent Electric Safe Initiation System) is specialized used as power supply for electric initiation (Electric Detonator, Igniter) as well as the DC power supply for magnetizing implement. By way of changing the position of the Wireline and the GND, we could also make the positive and negative current output respectively to achieve the purpose of initiation for twice.
The power supply fulfills the large current of AC output with wide voltage range, and uses the electronic isolation technology and current filter technology which could effectively isolate the grid and voltage (To prevent the leakage protection switch from tripping when initiating) and enhance the stability and antijamming capability of the output voltage to make it work more reliably. It also uses the over current time-delay protection circuit, which could automatically cutoff the output when the duration of ignition reaches two second and this can protect the control panel from breakdown.
This Intelligent Electric Safe Initiation System is used in concert with our Digital Electronic Explosion-proof Safety Switch, this would bring benefits of anti-static, anti-creep and preventing the operators from wrong operation as well, it overcomes the shortage of Mechanical Pressure Explosion-proof Safety Switch, thus preventing the occurrence of detonated by mistake on ground or perforated by mistake in the pit.
▶
Directions
- 1 Select the corresponding output voltage according to the detonator's initiating voltage. If the length of the electric cable is more than 3000 meters, it is necessary to add an additional voltage of 10V~30V according to its length to ensure the reliable initiation.
- 2 Connect the Wireline plug and GND correctly according to the requirement.
- 3 Turn on the power switch and safety switch successively, then push the Firing Switch button (for four seconds) when confirmed, finally release the button when there is no output current.
- 4 Turn off the power switch and safety switch successively, then unplug the Wireline plug and GND plug. The initiation control panel should be placed in a safe position after the operation has been finished.
⚙
Specifications
| Type | Input Voltage (V) | Output Voltage (V) | Input Current (A) | Output Current (A) | Continuous Operation Time (s) | Frequency (Hz) | Temperature Rating (°C) |
|---|---|---|---|---|---|---|---|
| HY-Ⅰ | 220 | 280~400 | 1.8 | ≤2A | 5 | 50~60 | -5~45 |
| HY-Ⅱ | 350~450 | 3 |
⚠
If you are not properly trained in the handling, and use of explosive devices, do not attempt the assembly of any FYPE Perforating Systems or Firing Devices.
?
Frequently Asked Questions
Q
What is the Intelligent Electric Safe Initiation System used for?
The Intelligent Electric Safe Initiation System (shooting panel) is designed as a power supply for electric initiation devices such as Electric Detonators and Igniters, as well as a DC power supply for magnetizing implements. It supports both positive and negative current output by changing the positions of the Wireline and GND connections, enabling initiation twice.
Q
How does the electronic isolation technology benefit the system?
The electronic isolation technology and current filter technology effectively isolate the grid voltage, preventing the leakage protection switch from tripping during initiation. This enhances the stability and anti-jamming capability of the output voltage, ensuring the system operates more reliably in demanding environments.
Q
What happens if the ignition duration exceeds two seconds?
The system is equipped with an over current time-delay protection circuit. If the duration of ignition reaches two seconds, the circuit will automatically cut off the output to protect the control panel from potential breakdown or damage.
Q
What additional voltage is required for cable lengths exceeding 3000 meters?
When the electric cable length exceeds 3000 meters, an additional voltage of 10V to 30V should be added based on the actual cable length. This ensures reliable and consistent initiation over long distances.
Q
What are the available models and their output voltage ranges?
Two models are available: HY-Ⅰ with an output voltage range of 280V–400V and a continuous operation time of 5 seconds, and HY-Ⅱ with an output voltage range of 350V–450V and a continuous operation time of 3 seconds. Both models operate on a 220V input and support frequencies of 50–60 Hz.
Q
How does this system work with the Digital Electronic Explosion-proof Safety Switch?
When used together with the Digital Electronic Explosion-proof Safety Switch, the system provides enhanced protection including anti-static, anti-creep, and prevention of wrong operator actions. This combination overcomes the limitations of Mechanical Pressure Explosion-proof Safety Switches, significantly reducing the risk of accidental detonation above ground or unintended perforation in the pit.