0102030405
China Wireline Modular Gun Perforating System Suppliers - Efficient Multi-Stage Plug-and-Perf Operations from Factory
The Wireline Modular Gun Perforating System is used for multi-stage plug-and-perf operations, featuring an integration of the switch and charge. The gun string can be fully built as a single block, and the plug-and-perf operation is fired by the shooting system in the field.
Graphic of Wireline Modular Gun Perforator
1. gun | 2. charge assembly | 3. snap ring | 4. protecter
Specifications
| Type | Thickness / Shot / Phasing / Charge... |
Maximum Stages |
Temperature Rating (°F) |
Category | Pressure Rating (MPa) |
|---|---|---|---|---|---|
| 60 | Depends on customers | 50 | 302 347 |
>1600 >1900 |
105 |
| 73 | 105, 140, 175 | ||||
| 80 | Multi-stage plug-and-perf operations orient Multi-stage plug and-perf operations | 140 | |||
| 86 | 140, 175 | ||||
| 89 | 105, 140, 175 |
Frequently Asked Questions (FAQ)
What is the primary application of the Wireline Modular Gun Perforating System?
The system is specifically engineered for multi-stage plug-and-perf operations in oil and gas completions, enabling the integration of switches and charges within a single block for reliable downhole performance.
What key components are integrated into the modular gun string?
Based on the structural configuration, the modular assembly consists of four critical parts: the gun body, the charge assembly, the snap ring, and the protector.
What are the available type dimensions and pressure ratings?
The modular perforator is available in Types 60, 73, 80, 86, and 89, with pressure ratings ranging from 105 MPa up to 175 MPa depending on the chosen model size.
What are the maximum stages and temperature limitations of the system?
The system can support up to 50 maximum stages per run and operates effectively within temperature ratings of 302°F and 347°F.
Can parameters such as shot density, phasing, and charge thickness be customized?
Yes, thickness, shot configuration, phasing, and charge options are entirely customizable based on specific well conditions and customer requirements.