01
Firing Head Systems for TCP Guns
Mechanical Firing Head with Drop Bar
The mechanical firing head is a debris-proof design used to fire guns in TCP operations. During operation, the drop bar is released at the wellhead, impacts the firing pin, shears the shear pin on the firing pin assembly, and then the firing pin strikes and detonates the detonator, thereby detonating the perforator.
Specifications
Type |
O.D. (mm) |
Pressure Rating (MPa) |
73 |
73 |
90 |
86 |
86 |
90 |
93 |
93 |
90 |
Safety Mechanical Firing Head
The Safety mechanical Firing Head is used in TCP to detonate guns. The safety mechanical firing head require both action, drop bar action unlock and hydrostatic actuate. Without enoughhy drostatic pressure acts on firing head, the impact detonator could not be detonated.
Specifications
Type |
O.D. (mm) |
Pressure Rating (MPa) |
73 |
73 |
140 |
86 |
86 |
140 |
93 |
93 |
140 |
Hydraulic Firing Head
The Hydraulic Firing Head is used for oil and gas well TCP completion operations, where it detonates the detonation tube or detonating cord to trigger the shaped charge. As a pressure detonator, it is activated by a wellhead pressurization device. This firing head was developed specifically for pressure-firing applications, including highly deviated and horizontal wells. It can be used with a time delay booster and can be placed either at the top or bottom of the TCP gun string.
Specifications
Type |
O.D. (mm) |
Charge Type |
43 |
43 |
90/140 |
51 |
51 |
90/140 |
73 |
73 |
90/140 |
80 |
80 |
90/140 |
86 |
86 |
90/140/175 |
93 |
93 |
90/140/175 |
Hydraulic Firing Head with Auto Vent
The hydraulic firing head with auto vent is a type of pressure detonator used in oil and gas well TCP completion operations. It is activated by applying pressure internally to the tubing string via a wellhead pressurization device, which detonates the detonation tube or detonating cord, thereby detonating the perforating guns and triggering the shaped charges.
Specifications
Type |
O.D. (mm) |
Pressure Rating (MPa) |
73 |
73 |
90/140 |
86 |
86 |
90/140/175 |
93 |
93 |
90/140/175 |
Top Dual Redundant Firing Head
The Top Dual Redundant Firing Head is designed to be run on top of a TCP gun string. It provides two independent methods to fire the percussion detonator and initiate the perforating gun string. This dual functionality is achieved by integrating an impact firing head into a pressure-activated firing head. Such redundancy gives operators the flexibility to choose either activation method, while also offering a backup in case the primary method fails to detonate the system.
Specifications
Type |
Perforator Type |
Charge Type |
73 |
73 |
90/140 |
80 |
80 |
90/140/175 |
86 |
86 |
90/140/175 |
93 |
93 |
90/140/175 |
Mechanical Firing Head with Automatic Gun Release
The Mechanical Firing Head with Automatic Gun Release enables operators to safely and reliably detonate and release the perforating assembly downhole. Activation is achieved by the impact of a drop bar: upon striking, the drop bar shears a safety retaining washer and drives the firing pin downward to initiate a percussion initiator. The resulting detonation propagates through the main body of the firing head, which then automatically releases the gun system into the wellbore. Once released, the perforating gun assembly drops away, leaving an open-ended tubing with a wireline entry guide in place.
Specifications
O.D. (mm) |
93 |
Pressure Rating (MPa) |
140 |
Min. Firing Hydrostatic (MPa) |
5 |
Min. Release Hvdrostatic (MPa) |
5 |
Min. Release Weights (Kg) |
150 |
I.D. After Release (mm) |
62 |
Max. Safe Weights (Kg) |
40,000 |
Hydraulic Firing Head with Automatic Gun Release
The Hydraulic Firing Head with Automatic Gun Release enables operators to safely and reliably detonate and release the perforating assembly downhole. Activation is achieved by applying hydraulic pressure. Upon pressure application, the resultant detonation propagates through the main body of the firing head, which then automatically releases the gun system into the wellbore. The perforating gun assembly drops away, leaving an open-ended tubing with a wireline entry guide in place.
Specifications
O.D. (mm) |
93 |
Pressure Rating (MPa) |
140 |
Min. Firing Hydrostatic (MPa) |
5 |
Min. Release Hvdrostatic (MPa) |
5 |
Min. Release Weights (Kg) |
150 |
I.D. After Release (mm) |
62 |
Max. Safe Weights (Kg) |
40,000 |