Leave Your Message
Products Categories
Featured Products

Shooting Panel (Intelligent Electric Safe Initiation System)

The shooting panel is designed to fire electronic detonators and igniters safety (positive or negative electrode) in perforating operation. It has self-checking circuit, voice reminding, earth leakage automatic protection, time-out power off, etc.

    Product Description

    The shooting panel (Intelligent Electric Safe Initiation System) is specialized used as power supply for electric initiation (Electric Detonator, Igniter) as well as the DC power supply for magnetizing implement. By way of changing the position of the Wireline and the GND, we could also make the positive and negative current output respectively to achieve the purpose of initiation for twice.
    The power supply fulfills the large current of AC output with wide voltage range, and uses the electronic isolation technology and current filter technology which could effectively isolate the grid and voltage (To prevent the leakage protection switch from tripping when initiating) and enhance the stability and antijamming capability of the output voltage to make it work more reliably. It also uses the over current time-delay protection circuit, which could automatically cutoff the output when the duration of ignition reaches two second and this can protect the control panel from breakdown. 
    This Intelligent Electric Safe Initiation System is used in concert with our Digital Electronic Explosion-proof Safety Switch, this would bring benefits of anti-static, anti-creep and preventing the operators from wrong operation as well, it overcomes the shortage of Mechanical Pressure Explosion-proof Safety Switch, thus preventing the occurrence of detonated by mistake on ground or perforated by mistake in the pit.
    Directions
    Select the corresponding output voltage according to the detonator’s initiating voltage. If the length of the electric cable is more than 3000 meters, it is necessary to add an additional voltage of 10V~30V according to its length to ensure the reliable initiation. 
    Connect the Wireline plug and GND correctly according to the as requirement.
    Turn on the power switch and safety switch successively, then push the Firing Switch button (for four seconds) when confirmed, finally release the button when there is no output current.
    Turn off the power switch and safety switch successively, then unplug the Wirline plug and GND plug. The initiation control panel should be placed in a safe position after the operation has been finished.

    Specifications

    Type

    Input Voltage

    (V)

    Output Voltage

    (V)

    Input

    Current

    (A)

    Output Current

    (A)

    Continuous Operation Time

    (s)

    Frequency (Hz)

    Temperature Rating

    (°C)

    HY-Ⅰ

    220

    280~400

    1.8

    ≤2A

    5

    50~60

    -5~45

    HY-Ⅱ

    350~450

    3

    If you are not properly trained in the handling, and use of explosive devices, do not attempt the assembly of any FYPE Perforating Systems or Firing Devices.

    Request A Quote
    Need a Consultation? Contact Us 24/7
    Describe your specific request*
    bg-contact